Data

常用 DIN2768 或 ISO2768 公差规格
 

According to DIN ISO 2768-1

Tabular 1 Limits for linear measures

Tolerance-class

Limits in mm for nominal sizes in mm

0,5 to 3

above
3 to 6

above    6 to 30

above   30 to 120

above 120 to 400

above 400
to 1000

above 1000
to 2000

above 2000
to 4000

f (fine)

± 0,05

± 0,05

± 0,1

± 0,15

± 0,2

± 0,3

± 0,5

-

m (medium)

± 0,1

± 0,1

± 0,2

± 0,3

± 0,5

± 0,8

± 1,2

± 2

c (coarse)

± 0,15

± 0,2

± 0,5

± 0,8

± 1,2

± 2

± 3

± 4

v (verycoarce grob)

-

± 0,5

± 1

± 1,5

± 2,5

± 4

± 6

± 8

For nominal sizes below 0,5 mm the limit measures are to be indicated directly at the nominal measure.

Tabular 2 Limit measures for radius of curvature and chamfer height

Tolerance class

Limits in mm for nominal sizes in mm

0,5

to 3

above 3

to 6

above 6

f (finne)

± 0,2

± 0,5

± 1

m (medium)

c (coarse)

± 0,4

± 1

± 2

v (very coarse)

For nominal sizes below 0,5 mm the limit measures are to be indicated directly at the nominal measure.

Tabular 3 Limit measures for chamfer height

Tolerance lass

Limits in mm for nominal sizes in mm

to 10

above 10

to 50

above 50

to 120

above 50

to 400

above 400

f (fine)

± 1 °

± 30 '

± 20 '

± 10 '

± 5 '

m (medium)

c (coarse )

± 1 ° 30 '

± 1 °

± 30 '

± 15 '

± 10 '

v (very coarce)

± 3 °

± 2 °

± 1 °

± 30 '

± 20 '


For nominal sizes below 0,5 mm the limit measures are to be indicated directly at the nominal measure. If general tolerances according to ISO 2768-1 are valid, the following has to be inserted in the title box, i.e. for tolerance class medium

ISO 2768 – m or general tolerance ISO 2768 – m

For new designs only the general tolerance according to DIN ISO 2768-1 should be valid. The limit measurements of the tolerance classes m and f of DIN ISO 2768-1 are identic with those of DIN 7168-1.

 

General tolerances for form and position

according to DIN ISO 2768-2

DIN ISO 2768-2 is for simplifying drawing and fixes general tolerances in three tolerance classes for form and position. By choosing a special tolerance class exactly the precision level common in workshops should be taken into account.

If smaller tolerances are needed or bigger are more economical these tolerances should be mentioned directly according to ISO 1101.

General tolerances for form and position should be used while the tolerance principle according. to ISO 8015 is valid and while this is mentioned in the drawing. This tolerance principles says that no opposite relation between measure, form and position tolerance exists (principle of superposition).

General tolerances for straightness and evenness in mm
Range of specified size in mm

Toleranceclass

to 10

above 10

to 30

above 30

to 100

above 100

to 300

above 300

to 1000

above 1000

to 3000

H

0,02

0,05

0,1

0,2

0,3

0,4

K

0,05

0,1

0,2

0,4

0,6

0,8

L

0,1

0,2

0,4

0,8

1,2

1,6

General tolerances for straightness and evenness in mm
Range of specified size in mm

Tolerance class

 

 

 

to 100

above 100

to 300

above 300

to 1000

above 1000

to 3000

H

0,2

0,3

0,4

0,5

K

0,4

0,6

0,8

1

L

0,6

1

1,5

2

General tolerances for symmetry
Range of specified size in mm

Tolerance class

 

 

to 100

above 100

to 300

above 300

to 1000

above 1000

to 3000

H

0,5

K

0,6

0,8

1